Case publishing guidelines

Last revised by Henry Knipe on 1 Feb 2024

Case publishing guidelines are here to help get an idea of the minimum set of expectations that we, as an editorial board, think are acceptable when uploading a case. 

A great way to get to grips with the process of uploading cases is to check out our Creating Cases Learning Pathway

As Radiopaedia gets larger and attracts a greater number of people from across the globe, we need to ensure that cases are as good as possible; these have evolved over the years, and as such, some older cases that you find on the site would no longer fulfill these guidelines (see: legacy cases).  

Please use these guidelines as a checklist prior to upload.

If cases do not meet these criteria, they will not be published. Instead, our editors will push these cases back to draft mode and ask you to either improve the case or keep it unlisted. In some instances (e.g. where there are patient confidentiality concerns) images or the entire case may need to be deleted. 

Guidelines

Permission

It is important that you have permission to upload the case from your institution. This will depend very much on your institution's departmental guidelines, and this varies a great deal from place to place. 

Many hospitals have guidelines that allow the publication of images provided they are appropriately de-identified, in line with their own privacy policies, without individual patient consent. Others require individual consent. Still, others have a blanket "no" approach. It is, therefore, your responsibility to establish that you are permitted to upload images. 

It is also worth considering if any of your colleagues will feel that they have a 'claim' to the images. This again will vary from place to place, as well as among individuals. You are welcome to add a "case courtesy of Dr X" in the case discussion section of the case. 

Copyright

The image must either be free of copyright restrictions or belong to you. Read more.

Plagiarism of images or text is absolutely unacceptable. Read more.

Patient confidentiality

All cases submitted should be completely de-identified, in such a way that an individual cannot be identified from the information uploaded. This is not as straightforward as it initially sounds as it will very much depend not only on direct information submitted but also on the rarity of the condition, the circumstances of presentation, the demographics of the patient and the specifics of your practice. For example, a common condition may be almost unique if your practice services a small population. 

Please take the time to review patient confidentiality

Thus, not only should images should be ideally devoid of ALL text overlay - this not only removes visual clutter but ensures that no information is inadvertently included - but care should be taken when assessing the suitability of publishing a case. 

Please note: We take this very seriously, and failure to abide by these rules constitutes a breach of our privacy policy and terms of use. If you upload a case with patient information, your case will be immediately deleted and if you repeatedly upload cases with patient details your account will be suspended. 

Patient consent 

Radiopaedia does not mandate patient consent to be obtained for all case contributions provided patient confidentiality is maintained and you abide by your local institution's policies. If in doubt, however, we urge you to err on the side of caution and obtain informed consent. You can download a consent form from Radiopaedia (see External links) or use your local consent form. If you do obtain consent please send a copy to [email protected]

Image quality

The vast majority of radiology departments now have PACS and with that, the ability to export images to disc. It is unlikely that taking a photograph of a screen will provide a case that is helpful for the illustration of a sign or disease process. 

Since our aim is to create the best radiology resource on the internet, we need good-quality images. Moreover, if the case includes cross-sectional imaging or DSA, the images should be uploaded as a stack. Ideally, these should be between 20-70 images per stack and excessive images (e.g. over 100) are generally discouraged; they take far too long to load and thus make your case difficult to access by most folk with lower speed connections. 

You consider using one of our third-party uploaders. These make uploading cases a breeze. 

Appearance
  1. resolution: no specific figure is set. The minimum is the native resolution of the modality (e.g. 512x512px for CT, 128 to 1024px for MRI (depending on sequence / scan parameters), >1024px for plain films, etc). 

  2. contrast/brightness: the abnormality should be visible easily and the image displayed with optimum windowing and levels (remember that these are not DICOM and therefore should be optimized at the time of capture).

Images should also be cropped appropriately so that there is no extraneous amount of blank space around them - read more

Text overlays and watermarks

Obviously, images should include zero identifying information (see above). The best way to do this is to have zero text overlays.

The benefits of having no text overlays whatsoever are manifold:

  • ensures no patient information

  • ensures that no one interprets text as patient information (even if it is not)

  • makes the image look great

  • makes it easier to use the image in presentations

If you want to include an arrow or annotation,  please upload a separate 'annotated' version of a single image demonstrating an ROI measurement is best.

For clinical images, no watermarks, logos or other graphics should be on the image. This includes: 

  • your name or logo or signature

  • your institution's logo or name

  • the brand of your PACS or viewer or image processor

  • watermarks over the image of any kind

There are a couple of exceptions:

  • manufacturer logos are sometimes burnt into the images (particularly ultrasound); if possible remove these also

  • your signature and creative commons logo on illustrations (see medical illustrations and diagrams for more information)

Diagnosis

Cases need to have a diagnosis, and each case has a diagnostic certainty slider at the top of the case to help you. This may be radiological (e.g. supracondylar fracture) or histological (e.g. eosinophilic granuloma). It is important that if the diagnosis is histological, an appropriate mention is made in the discussion. Ideally, you should include the histology report (and even better - images of the slides).

If the diagnosis is a presumptive diagnosis pending histological confirmation, this should be clarified in the text; please give strong consideration to delaying publication until this is received.

In some cases, where no laboratory or pathological test is definitive, the diagnosis is presumptive. In such cases, you need to convince the readers/editors why your diagnosis is correct. In common conditions where the diagnosis has not been established (e.g. diagnostic certainty possible or probable) and when further imaging or pathology is usually available, the case may not be published. 

Imaging modality

The imaging modality should be appropriate for the diagnosis, e.g. rectal MRI for rectal cancer. In some cases, a diagnosis on a not typical modality is of interest, (e.g. fracture on ultrasound) but this should be clearly noted in the case discussion. In addition, the protocol should also be appropriate and meet consensus guidelines for best practice, or when there is deviation from these guidelines this should be clearly mentioned in the case discussion. 

Study findings

Just because you know what the image or stack of images shows, it does not mean that everybody does! It does not need to be a complete report but should highlight the salient features, particularly, the study findings should provide a minimum data set for the diagnosis, particularly where consensus or diagnostic guidelines apply. 

Questions

These are not mandatory, but can turn a good case into a great case!

Discussion

The discussion portion of the case is not mandatory but can be helpful for more complex cases. It should be limited to this case and delegate discussion of the condition in general to the "related article" section (see below).  You can link some keywords to articles in Radiopaedia (read more about linking).

When discussing a case, it is advised to avoid using terms that may express inadequate emotions. Such as referring to a case as nice or interesting. Here are some replacement suggestions of some commonly used terms that could be avoided:

  • good/nice example - typical/classic example

  • beautiful case of - well-illustrated case of

  • good/interesting case - helpful/instructive case; uncommon/unusual case

  • bizarre/interesting case - uncommon/rare/unusual case

Related articles

At the end of each case please add relevant related Radiopaedia articles (minimum of one, but usually two or three).

External links

If any of these links are broken or for other problems and questions, please contact [email protected].

ADVERTISEMENT: Supporters see fewer/no ads

Updating… Please wait.

 Unable to process the form. Check for errors and try again.

 Thank you for updating your details.