Chest x-ray: PICC position (summary)

Dr Jeremy Jones et al.

Chest x-ray PICC (peripherally inserted central catheter) position should be assessed following initial placement and on subsequent radiographs.

Reference article

This is a summary article; we do not have a more in-depth reference article.

Summary

  • insertion
    • usually inserted via the antecubital fossa
    • threaded proximally without image guidance
    • chest x-ray performed afterwards to check position
    • tip should sit at the superior cavoatrial junction
  • assessing position
    • window the image to best visualise the line
    • trace the line from its insertion up the arm towards the axilla
    • trace the line under the clavicle towards the SVC
    • trace the line towards the heart
      • ensure that the line does not turn cranially
    • visualise the tip of the line
      • tip should be at the cavoatrial junction
    • document the position of the line
  • potential malposition
    • tip too high: proximal SVC
    • tip too low: distal right atrium or right ventricle
    • tip in the right internal jugular vein
    • tip in the azygous vein
    • coiled in the axillary/subclavian vein
  • possible complications
    • tip too high: increased risk of thrombus formation
    • tip too low: increased risk of arrhythmia
Medical student radiology curriculum
Share article

Article information

rID: 39663
Systems: Vascular, Chest
Section: Approach
Synonyms or Alternate Spellings:

Support Radiopaedia and see fewer ads

Cases and figures

  • Drag
    Area to review
    Drag here to reorder.
  • Drag
    Correct position
    Drag here to reorder.
  • Updating… Please wait.
    Loadinganimation

    Alert accept

    Error Unable to process the form. Check for errors and try again.

    Alert accept Thank you for updating your details.