Citation, DOI, disclosures and article data
Citation:
Gaillard F, Walizai T, Thibodeau R, et al. Dehiscent jugular bulb. Reference article, Radiopaedia.org (Accessed on 11 Oct 2024) https://doi.org/10.53347/rID-1205
Dehiscent jugular bulbs are present when the sigmoid plate between a high riding jugular bulb and the middle ear is absent, allowing the wall of the jugular bulb to bulge into the middle ear cavity.
The estimated incidence is ~5% (range 3.5-7%) of the symptomatic population (e.g. those with tinnitus) 4,5.
It is one of the causes of pulsatile tinnitus and is a common cause of a retrotympanic vascular mass.
Patients can present with conductive hearing loss. This may occur when the jugular bulb contacts the tympanic membrane, interferes with the ossicular chain, or obstructs the round window 9.
given the often turbulent flow within the jugular bulb, the signal on MRI can be confusing
the presence of the sigmoid plate can only be ascertained on CT
Clearly, if it is mistaken for a middle ear tumor and biopsied, then the consequences can be disastrous (as is biopsying an aberrant internal carotid artery).
-
1. Swartz JD, Harnsberger HR. Imaging of the temporal bone. George Thieme Verlag. (1998) ISBN:0865777004. Read it at Google Books - Find it at Amazon
-
2. Krishnan A, Mattox DE, Fountain AJ et-al. CT arteriography and venography in pulsatile tinnitus: preliminary results. AJNR Am J Neuroradiol. 2006;27 (8): 1635-8. AJNR Am J Neuroradiol (full text) - Pubmed citation
-
3. Harnsberger HR, Glastonbury CM, Michel MA et-al. Diagnostic Imaging: Head and Neck. Lippincott Williams & Wilkins. (2010) ISBN:1931884781. Read it at Google Books - Find it at Amazon
-
4. Atmaca S, Elmali M, Kucuk H. High and dehiscent jugular bulb: clear and present danger during middle ear surgery. Surgical and radiologic anatomy : SRA. 36 (4): 369-74. doi:10.1007/s00276-013-1196-z - Pubmed
-
5. Sayit AT, Gunbey HP, Fethallah B, Gunbey E, Karabulut E. Radiological and audiometric evaluation of high jugular bulb and dehiscent high jugular bulb. The Journal of laryngology and otology. 130 (11): 1059-1063. doi:10.1017/S0022215116009166 - Pubmed
-
6. S. Vattoth, R. Shah, J.K. Curé. A Compartment-Based Approach for the Imaging Evaluation of Tinnitus. American Journal of Neuroradiology. 31 (2): 211. doi:10.3174/ajnr.A1704 - Pubmed
-
7. Oztürkcan S, Katilmiş H, Ozkul Y, Erdoğan N, Başoğlu S, Tayfun MA. Surgical treatment of the high jugular bulb by compressing sinus sigmoideus: two cases. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 265 (8): 987-91. doi:10.1007/s00405-007-0545-0 - Pubmed
-
8. El-Begermy MA, Rabie AN. A novel surgical technique for management of tinnitus due to high dehiscent jugular bulb. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 142 (4): 576-81. doi:10.1016/j.otohns.2009.12.007 - Pubmed
-
9. Weiss RL, Zahtz G, Goldofsky E, Parnes H, Shikowitz MJ. High jugular bulb and conductive hearing loss. (1997) The Laryngoscope. 107 (3): 321-7. Pubmed