Globe rupture

Changed by Henry Knipe, 24 Jun 2022
Disclosures - updated 6 Apr 2022:
  • Radiopaedia Events Pty Ltd, Speaker fees (past)
  • Integral Diagnostics, Shareholder (ongoing)
  • Micro-X Ltd, Shareholder (ongoing)

Updates to Article Attributes

Body was changed:

Globe rupture is an ophthalmologic emergency. A ruptured globe or an open-globe injury must be assessed in any patient who has suffered orbital trauma because open-globe injuries are a major cause of blindness.

In blunt trauma, ruptures are most common at the insertions of the intraocular muscles where the sclera is thinnest. 

Clinical presentation

If intraocular contents are visualised at clinical examination, a diagnosis of a ruptured globe can be obvious. 

Pathology

Aetiology

Globe rupture is traumatic in the vast majority of cases:

  • penetrating trauma
  • blunt trauma
  • chemical e.g. strong acids, alkalis

Rarely atraumatic spontaneous rupture is seen, e.g. patients with coexisting severe glaucoma and scleromalacia perforans.

Radiographic features

CT

Unenhanced, thin-section axial axial CT scans with multiplanar reformation is the CT mode of choice 2.

CT findings that can be present in a globe rupture include 1:

  • collapsed globe ("flat tyre" or "mushroom" appearance)
  • presence of intraocular gas or a foreign body
  • thick posterior sclera
  • hazy outline of the globe
  • abnormal anterior chamber size (enlarged in posterior rupture, decreased in anterior rupture)
Ultrasound

While obvious globe rupture is a contraindication to ocular ultrasonography, less obvious cases may be incidentally detected with ultrasonography after ocular trauma. Findings consistent with globe rupture include 5:

  • decreased anterior chamber (AC) depth (and/or collapse)
    • anterior chamber may also contain layering, homogenous echogenic debris consistent with hyphaema
  • decreased globe volume
    • with loss of spherical contour
  • posterior scleral buckling
  • intraocular or periocular air
    • scattered echogenicities with "dirty" acoustic shadowing
CT

Unenhanced, thin-section axial axial CT scans with multiplanar reformation is the CT mode of choice 2.

CT findings that can be present in a globe rupture include 1:

  • collapsed globe ("flat tyre" or "mushroom" appearance)
  • presence of intraocular gas or a foreign body
  • thick posterior sclera
  • hazy outline of the globe
  • abnormal anterior chamber size (enlarged in posterior rupture, decreased in anterior rupture)
  • -</ul><p>Rarely atraumatic spontaneous rupture is seen, e.g. patients with coexisting severe glaucoma and <a href="/articles/scleromalacia-perforans">scleromalacia perforans</a>.</p><h4>Radiographic features</h4><h5>CT</h5><p>Unenhanced, thin-section axial axial CT scans with multiplanar reformation is the CT mode of choice <sup>2</sup>.</p><p>CT findings that can be present in a globe rupture include <sup>1</sup>:</p><ul>
  • -<li>collapsed globe ("flat tyre" or "mushroom" appearance)</li>
  • -<li>presence of intraocular gas or a foreign body</li>
  • -<li>thick posterior sclera</li>
  • -<li>hazy outline of the globe</li>
  • -<li>abnormal anterior chamber size (enlarged in posterior rupture, decreased in anterior rupture)</li>
  • -</ul><h5>Ultrasound</h5><p>While obvious globe rupture is a contraindication to ocular ultrasonography, less obvious cases may be incidentally detected with ultrasonography after ocular trauma. Findings consistent with globe rupture include <sup>5</sup>:</p><ul>
  • +</ul><p>Rarely atraumatic spontaneous rupture is seen, e.g. patients with coexisting severe glaucoma and <a href="/articles/scleromalacia-perforans">scleromalacia perforans</a>.</p><h4>Radiographic features</h4><h5>Ultrasound</h5><p>While obvious globe rupture is a contraindication to ocular ultrasonography, less obvious cases may be incidentally detected with ultrasonography after ocular trauma. Findings consistent with globe rupture include <sup>5</sup>:</p><ul>
  • +</ul><h5>CT</h5><p>Unenhanced, thin-section axial axial CT scans with multiplanar reformation is the CT mode of choice <sup>2</sup>.</p><p>CT findings that can be present in a globe rupture include <sup>1</sup>:</p><ul>
  • +<li>collapsed globe ("flat tyre" or "mushroom" appearance)</li>
  • +<li>presence of intraocular gas or a foreign body</li>
  • +<li>thick posterior sclera</li>
  • +<li>hazy outline of the globe</li>
  • +<li>abnormal anterior chamber size (enlarged in posterior rupture, decreased in anterior rupture)</li>

Systems changed:

ADVERTISEMENT: Supporters see fewer/no ads