Image guided percutaneous renal biopsy

Dr Ian Bickle et al.

Image guided percutaneous renal biopsy, utilising either ultrasound or CT allows for an accurate, reliable method of acquiring renal tissue for histopathological assessment.

Biopsy may be of a native or transplant kidney. It is divided into two types:

  • non-focal or non-targeted
  • focal or targeted (i.e. directed at a lesion)

Either type may be performed as a CT guided biopsy or as an ultrasound guided biopsy 1. Recent description has been given of the use of 3D cone beam CT in assisting the biopsy of particularly challenging focal lesions 2.

This depends on both patient and operator factors, such as patient body habitus, ability to cooperate and operator experience. Transplant renal biopsy is usually undertaken with ultrasound guidance given its more superficial location in the pelvis.

An alternative option for percutaneous CT/US guidance is the transjugular renal biopsy.

  • focal lesion non-characterised on diagnostic imaging
  • renal failure with unknown cause (typically a nephropathy)
  • deteriorating renal function in a transplant patient

For focal mass lesions the established indications include:

  • known extra-renal malignancy
  • suspected renal lymphoma
  • prior to ablation therapy
  • multiple or bilateral renal masses
  • diagnostic dilemma of infection/malignant mass

The contraindications must be considered individually in each case. Overall, the most important contraindications are:

  • uncooperative patient
  • uncorrectable bleeding diathesis (abnormal coagulation indices)
Laboratory parameters for a safe procedure

Interventional procedures like renal biopsy require special attention to coagulation indices. There are widely divergent opinions about the safe values of these indices for percutaneous biopsies. The values suggested below were considered based on literature review, whose references are cited below:

  • complete (full) blood count:
    • platelet > 50000/mm3  (some institutions determine other values between 50000-100000/mm3) 3
  • coagulation profile:
    • some studies showed that having a normal INR or prothrombin time is no reassurance that the patient will not bleed after the procedure:
      • international normalized ratio (INR) ≤ 1.5 3
      • normal prothrombin time (PT)/partial thromboplastin time (PTT)
Pre-procedure preparation
  • written informed consent
  • assessment of patient's cooperation for procedure
Equipment
  • single or co-axial needle set: usually an 18G core biopsy needle
  • 1% lidocaine/lignocaine
  • midazolam (for sedation): select cases only; assess on a case-by-case basis
  • histopathology department pots for 'dry' and 'wet' core
Technique

Focal biopsies usually require only a single core. Non-focal biopsies typically require two cores. This influences technique as the latter requires a co-axial needle set.

For native or transplant non-focal kidney biopsies, the core is usually taken from the lower pole.

Both ultrasound and CT biopsies are normally performed with the patient prone or on occasion on the ipsilateral side up position in CT. Transplant biopsies are performed supine due to the superficial position in the pelvis.

CT guidance is preferred for those of larger body habitus. Operator preference plays a part too.

After the procedure, a brief assessment for perinephric or intraparenchymal haemorrhage is advised.

Post-procedure care

Bed-rest is advised as well as regular observations for 4 hours (pulse, blood pressure, SpO2) and active questioning to the patient of any pain or haematuria.

The observation period should allow an ample opportunity to identify and treat a potential complication in a timely manner to prevent a serious or catastrophic outcome, this varies with each institution's protocol. One large experience review major complications were identified in >90% of cases by 24 hours 4.

Percutaneous renal biopsy remains a safe procedure, but the risk of complication is higher in patients with advanced renal insufficiency 4. Some studies have also shown that hypertension and amyloidosis has significant influence on the complications 5. These patients may benefit from a longer observation period.

Complications include:

Tissue sample adequacy

Adequacy depends on the disease in question.

In diseases with focal changes (e.g. focal and segmental glomerulosclerosis), at least 10 glomeruli would be optimal.

Even diseases with diffuse changes (e.g. membranous glomerulonephritis), show variation in terms of severity, therefore at least 5-10 glomeruli required to properly assess the extent and severity of the disease. Recommend two biopsy cylinders with a diameter of at least 1.2 mm

Histopathological analysis
Core 1

Fixed in paraffin then used for the following staining procedures for light microscopy:

A: Routine stains:

  • Haematoxylin and eosin (H&E)
  • Periodic acid-Schiff’s (PAS)
  • Fibrous tissue stain (e.g.elastic van Gieson etc)
  • Silver stain

B: Optional stains:

  • Kossa stain (calcifications)
  • Congo red stain (amyloid)

C: Immunohistochemistry: IgG, IgA, IgM, C3, C1q

Core 2

Used for immunofluorescence studies (frozen sections), electron microscopy (fixed in glutaraldehyde) and additional tests.

Not every biopsy requires electron microscopy. Some conditions (e.g. Alport’s disease; immunotactoid disease; minimal change nephropathy) require electron microscopy for definite diagnosis.

Kindly contributed by Dr E Lim, Consultant Pathologist, RIPAS Hospital, Brunei.

Share article

Article Information

rID: 21865
Synonyms or Alternate Spellings:
  • Ultrasound guided renal biopsy
  • CT guided renal biopsy
  • Renal biopsy
  • Kidney biopsy
  • Percutaneous renal biopsy
  • Image guided renal biopsy

Support Radiopaedia and see fewer ads

Cases and Figures

  • Drag
    A typical co-axia...
    Figure 1: co-axial needle set for procedure
    Drag here to reorder.
  • Drag
    The needle 'open'...
    Figure 2: needle 'open' showing 2cm core
    Drag here to reorder.
  • Drag
    Case 1: ultrasound guided
    Drag here to reorder.
  • Drag
    Case 2: CT guided renal biopsy: non-focal
    Drag here to reorder.
  • Drag
    Case 3: clear cell RCC - biopsy
    Drag here to reorder.
  • Drag
    Case 4: with large post biopsy haemorrhage
    Drag here to reorder.
  • Drag
    Case 5: with post biopsy perirenal haematoma
    Drag here to reorder.
  • Drag
    Case 6: CT guided: focal mass
    Drag here to reorder.
  • Drag
    Co-axial needle '...
    Case 7: CT guided: non focal
    Drag here to reorder.
  • Updating… Please wait.
    Loadinganimation

    Alert accept

    Error Unable to process the form. Check for errors and try again.

    Alert accept Thank you for updating your details.