Maximum intensity projection
Citation, DOI, disclosures and article data
At the time the article was created Bruno Di Muzio had no recorded disclosures.
View Bruno Di Muzio's current disclosuresAt the time the article was last revised Andrew Murphy had no financial relationships to ineligible companies to disclose.
View Andrew Murphy's current disclosures- MIP
- Maximum intensity projection (MIP)
- Sliding thin-slab maximum intensity projection (STS-MIP)
Maximum Intensity Projection (MIP) consists of projecting the voxel with the highest attenuation value on every view throughout the volume onto a 2D image 1.
Such an algorithm is rather simple: for each XY coordinate, only the pixel with the highest Hounsfield number along the Z-axis is represented so that in a single bidimensional image all dense structures in a given volume are observed. For example, it is possible to find all the hyperdense structures in a volume, independently of their position 2.
This method tends to display bone and contrast material-filled structures preferentially, and other lower-attenuation structures are not well visualized 2. The primary clinical application of MIP is to improve the detection of pulmonary nodules and assess their perfusion. MIP also helps characterize the distribution of small nodules. In addition, MIP sections of variable thickness are excellent for assessing the size and location of vessels, including the pulmonary arteries and veins 1.
History and etymology
The American radiologist, working in Stanford, California, Sandy Napel (fl. 2019) et al introduced sliding thin-slab maximum intensity projection (STS-MIP) as a new technique in 1993 3.
References
- 1. Cody DD. AAPM/RSNA physics tutorial for residents: topics in CT. Image processing in CT. Radiographics. 22 (5): 1255-68. Radiographics (full text) - Pubmed citation
- 2. Perandini S, Faccioli N, Zaccarella A et-al. The diagnostic contribution of CT volumetric rendering techniques in routine practice. Indian J Radiol Imaging. 2010;20 (2): 92-7. doi:10.4103/0971-3026.63043 - Free text at pubmed - Pubmed citation
- 3. Napel S, Rubin GD, Jeffrey RB. STS-MIP: a new reconstruction technique for CT of the chest. (1993) Journal of computer assisted tomography. 17 (5): 832-8. Pubmed
Incoming Links
- Combined conduit score of sinovenous stenosis
- CT angiography of the cerebral arteries (protocol)
- Minimum intensity projection (MinIP)
- Saccular cerebral aneurysm
- Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia
- Multiplanar reformation (MPR)
- Gastrointestinal angiodysplasia
- Hereditary haemorrhagic telangiectasia (liver manifestations)
- Fraley syndrome
- Tree-in-bud pattern
- Medical abbreviations and acronyms (M)
- Minimal aortic injury
- Magnetic resonance cholangiopancreatography (MRCP)
- Single phase CT angiographic collateral scores in acute stroke
- CT angiography of the splanchnic vessels (protocol)
- Background parenchymal enhancement (breast MRI)
- Lung torsion
- Saddle pulmonary artery embolism
- Abnormal perfusion scintigraphy
- Normal perfusion scintigraphy
- Paget–Schroetter syndrome - thromboaspiration
- Excipient lung disease
- Intracerebral arteriovenous malformation
- Left MCA occlusion - thrombectomy
- Rupture of ureter due to calculi
- Supernumerary kidney
- Mediastinal hematoma secondary to bronchial artery laceration following endobronchial ultrasound-guided (EBUS) biopsy
- Femoral facial syndrome
- Normal chest CT
- Aneurysmal subarachnoid haemorrhage (modified Fisher grade 4) and bihemispheric anterior cerebral artery
- Mobin-Uddin umbrella filter
- Bilateral pulmonary emboli
Related articles: Computed tomography
- computed tomography in practice
-
computed tomography overview
- iodinated contrast media
- CT IV contrast media administration
-
CT artifacts
- patient-based artifacts
- physics-based artifacts
- hardware-based artifacts
- ring artifact
- tube arcing
- out of field artifact
- air bubble artifact
- helical and multichannel artifacts
- CT technology
-
generations of CT scanners
- helical CT scanning
- step and shoot scanning
- ultra-high-resolution CT (UHRCT)
- CT x-ray tube
- CT fluoroscopy
- cone-beam CT
-
generations of CT scanners
- dual-energy CT
- CT image reconstruction
- CT image quality
- CT dose
-
CT protocols
- composite
- head & neck
- chest
- abdomen and pelvis
- CT abdomen-pelvis (protocol)
- CT abdominal aorta
- CT adrenals (protocol)
- CT cholangiography (protocol)
- CT colonography (protocol)
- CT enteroclysis (protocol)
- CT enterography (protocol)
- CT gastrography (protocol)
- CT kidneys, ureters and bladder (protocol)
- CT urography (protocol)
- CT Renal mass (protocol)
- CT angiography of the splanchnic vessels (protocol)
- CT renal split bolus
- CT pancreas (protocol)
- liver