Out of field artifact
Citation, DOI, disclosures and article data
At the time the article was created Daniel J Bell had no recorded disclosures.
View Daniel J Bell's current disclosuresAt the time the article was last revised Daniel J Bell had no financial relationships to ineligible companies to disclose.
View Daniel J Bell's current disclosures- Incomplete projection artifact
- Incomplete projection artefact
- Out of field artefact
- Incomplete projection artifacts
- Incomplete projection artefacts
- Out of field artefacts
- Out of field artifacts
Out of field artifact, also known as incomplete projection artifact, is due to part of the patient existing peripheral to the field of view of the CT scanner. This can be a particular issue in obese patients who only just fit within the scanner bore.
The lack of data from these out of field tissue/objects interferes with the ability of the software to generate a correct image leading to streaking, and areas of unusual increased or decreased density. At best this is a mere annoyance, at worst it may render the images uninterpretable.
A contributing factor, especially in obese patients, may be the obstruction of reference channels of the x-ray detectors, which can also produce streaking artifact.
Preventing this artifact relies on the CT operator ensuring that the body of the patient lies wholly within the scan field or - in the case of the arms - place them up or down depending upon whether the head and neck or chest and body are being scanned.
References
- 1. Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. (2004) Radiographics : a review publication of the Radiological Society of North America, Inc. 24 (6): 1679-91. doi:10.1148/rg.246045065 - Pubmed
Incoming Links
Related articles: Computed tomography
- computed tomography in practice
-
computed tomography overview
- iodinated contrast media
- CT IV contrast media administration
-
CT artifacts
- patient-based artifacts
- physics-based artifacts
- hardware-based artifacts
- ring artifact
- tube arcing
- out of field artifact
- air bubble artifact
- helical and multichannel artifacts
- CT technology
-
generations of CT scanners
- helical CT scanning
- step and shoot scanning
- ultra-high-resolution CT (UHRCT)
- CT x-ray tube
- CT fluoroscopy
- cone-beam CT
-
generations of CT scanners
- dual-energy CT
- CT image reconstruction
- CT image quality
- CT dose
-
CT protocols
- composite
- head & neck
- chest
- abdomen and pelvis
- CT abdomen-pelvis (protocol)
- CT abdominal aorta
- CT adrenals (protocol)
- CT cholangiography (protocol)
- CT colonography (protocol)
- CT enteroclysis (protocol)
- CT enterography (protocol)
- CT gastrography (protocol)
- CT kidneys, ureters and bladder (protocol)
- CT urography (protocol)
- CT Renal mass (protocol)
- CT angiography of the splanchnic vessels (protocol)
- CT renal split bolus
- CT pancreas (protocol)
- liver