Umbilical venous flow assessment

Umbilical venous flow in the physiological situation comprises of a monophasic non pulsatile flow pattern with a mean velocity of ~10-15 cm/s. The presence of pulsatility implies a pathological state unless in the following situations:

  • early in pregnancy: up to ~13 weeks gestation 
    • the presence of pulsatility may be higher in chromosomally abnormal fetuses even in early pregnancy 5
  • when confounded by other movement variables such as 
    • fetal breathing movement
    • fetal hiccups 1

Pulsations of the umbilical venous system, especially double pulsations have been associated with increase in the perinatal mortality when associated with the absent and reversed end-diastolic flow velocity in the umbilical artery.