Accidental foreign body aspiration (seamstress needle)

Case contributed by Dr Domenico Nicoletti

Presentation

Needle accidental aspiration during sewing

Patient Data

Age: 30 years
Gender: Female
X-ray

Chest and abdomen

In the anterior basal segment of the left lower lobe there is a needle. Pneumothorax is not detectable.

Needle in an anterior segmental bronchus of the left lower lobar bronchus. A tracheal diverticulum is present as an accidental discovery.

Bronchoscopy

Failed.             

Surgical therapy

Resection anterior basal segment of the left lower lobe.

Case Discussion

Aspiration of foreign bodies from the airways is diagnosed in the early stages because it causes symptoms such as dyspnea, wheezing, coughing and screeching as in this patient. In some cases the diagnosis can be difficult due to the absence of typical symptoms or if the foreign body is not radiopaque. CT is the first imaging modality to better study an aspirated foreign body in the bronchial tree. Associated findings on CT can be volume loss, bleeding, hyperlucency with air trapping in the affected lobe.

PlayAdd to Share

Case information

rID: 77740
Published: 20th May 2020
Last edited: 23rd May 2020
System: Chest
Inclusion in quiz mode: Included