Presentation
Right upper chest trauma and pain after falling from 6 meters at work.
Patient Data



An increase in the acromioclavicular joint space. Coracoid process fracture. No shoulder dislocation.



Displaced coracoid process fracture. The acromioclavicular joint is outside the field of view.
Subcutaneous emphysema is also noted.



Fixation of acromioclavicular joint by K-wire with good alignment. No hardware fracture or clavicular fracture. Coracoid process fracture.
Case Discussion