Endoleak: type II

Case contributed by RMH Core Conditions

Presentation

Post EVAR repair. Surveillance.

Patient Data

Age: 91
Gender: Male
Modality: CT

The stent graft is seen within the abdominal aorta. Proximally, it arises from above the origin of the renal arteries. Trouser insertions into the common iliac arteries bilaterally.

Multiple retroleaks identified. The anterior leaks are due to collaterals via the inferior mesenteric artery. The posterior leaks are due to collaterals from the lumbar arteries.

The AP diameter measures 9 cm with cheers is larger than the measurement is ultrasound (7.2 cm).

Polycystic kidneys noted. Marked cardiomegaly.

Conclusion:

Type 2 endoleak.