Foreign body induced tenosynovitis of finger
Presentation
History of thorn injury to finger - 15 days. Complains of swelling + pain.
Patient Data
Age: 25
Gender: Male
From the case:
Foreign body induced tenosynovitis of finger
Ultrasound
Loading images...

Longitudinal
Linear echogenic focus (3 mm) is noted abutting flexor tendon near the base of the middle phalanx. It is on the radial aspect. It is within tendon sheath. Synovial sheath thickening with mild fluid is noted in tendon sheath. No tear is noted. No PID or DIP joint effusion is noted.