Scapular notching in reverse shoulder arthroplasty

Case contributed by Domenico Nicoletti , 10 Nov 2016
Diagnosis almost certain
Changed by Matt Skalski, 13 Nov 2016

Updates to Study Attributes

Findings was changed:

There is erosion of the lower edge of the scapular glenoid due to impingement of the humeral insert humeral versus the scapula.

Updates to Case Attributes

Body was changed:

With this type of prosthesis the center of rotation is placed in theshifted medial of about 2 cm in order to increase the lever arm of the deltoid muscle.

This solution increases the abilityrisk of the glenoid erosion and instability of glenosphere.

To overcome this risk are madethe prosthesis glenosphereis enlarged, lowered and tilted medially (glenosphere eccentric) while on thethe humeral insert humeral you createdcreates a medial recess.

  • -<p>With this type of prosthesis the center of rotation is placed in the medial of about 2 cm in order to increase the lever arm of the deltoid muscle.</p><p>This solution increases the ability of the glenoid erosion and instability of glenosphere.</p><p>To overcome this risk are made prosthesis glenosphere enlarged, lowered and tilted medially (glenosphere eccentric) while on the insert humeral you created a medial recess</p>
  • +<p>With this type of prosthesis the center of rotation is shifted medial about 2 cm in order to increase the lever arm of the deltoid muscle.</p><p>This solution increases the risk of glenoid erosion and instability of glenosphere.</p><p>To overcome this risk the prosthesis is enlarged, lowered and tilted medially (glenosphere eccentric) while the humeral insert creates a medial recess.</p>