There is a complete tear of the EHL tendon. The fluid-filled gap between the two tendon edges is about 35 - 40 mm. Floating sutures are present in the fluid gap. The proximal torn end is at the level of the tarsometatarsal joint. The distal end is at the metatarso-phalangeal joint level.
With great toe passive movement (dynamic scan), there was no movement of the proximal tendon.